Commercial Refrigerator
Product Details
Small refrigerated containers mainly consist of sheet metal shells, heat exchangers, fans, compressors, and controllers. When the indoor 50W small refrigeration box is running, the refrigerant is mainly sucked in through the compressor. After being sucked into the compressor, the refrigerant is compressed by the compressor and becomes a high-temperature and high-pressure gaseous refrigerant. After compression, the refrigerant is transported to the condenser through a pipeline. In the condenser, the refrigerant begins to release heat. After condensation, the high-temperature and high-pressure gaseous refrigerant becomes a low-temperature and high-pressure liquid refrigerant. After condensation, the refrigerant enters the capillary tube and is reduced by the throttle pressure of the capillary tube. Finally, it enters the evaporator. The low-temperature and low-pressure liquid refrigerant enters the evaporator and quickly absorbs heat and evaporates, eventually becoming an isothermal and isobaric gaseous refrigerant. Afterwards, the gaseous refrigerant is sucked and compressed again by the compressor, Continue the refrigeration cycle. As the refrigerant evaporates and absorbs heat, the temperature in the refrigerator also decreases, ultimately achieving the effect of refrigeration.
Key Features:
- Customized cooling capacity of 50-70W
- Adopting internationally renowned brand compressors to ensure a ten-year service life of the refrigeration system
- Integrated design, compact structure
Application:
- Refrigeration of fruit juice and milk
Item | Description | UU05-A1BQY | UU07-A1BQY |
Parameters | Customized cooling capacity (W) @ 2-5/L32 | 50 | 70 |
Rated cooling power (W) | 50 | 66 | |
Refrigerant | R600 | ||
Noise dB(A) | ≤55 | ||
Protection grade | IP55 | ||
Operating ambient temperature range (℃) | -5~+43℃ | ||
Power spec. | AC220-240V 50&60Hz 、AC110-115V 60Hz | ||
Size H*W*D(mm) | 574 x 197 x 447 | 687 x 264 x 478.4 | |
Appearance | Brushed stainless steel | ||
Weight(kg) | 28 | 33 |
Product Classification
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER
Services & Support
About BEEHE