LSJ series energy storage chiller
The LSJ series energy storage air-cooled chiller adopts compression active cooling technology, which transports low-temperature cooling water through primary, secondary, and tertiary pipelines to the energy storage liquid cooling plate. The energy storage liquid cooling plate directly contacts the battery pack, absorbing the heat generated during the battery charging and discharging process and returning it to the internal plate heat exchanger of the chiller. The high-temperature cooling medium completes heat exchange with the low-temperature refrigerant inside the plate heat exchanger, and conducts heat to the condenser through the refrigerant and dissipates it to the external environment. The cooled medium is transported again to the liquid cooling plate through a circulation pump for the next cycle, thereby keeping the temperature of the battery pack within a safe range.
Key Features:
- Customized cooling capacity of 5-60kW
- Adopting internationally renowned brand compressors to ensure a ten-year service life of the refrigeration system
- Variable frequency refrigeration system, which can automatically adjust the cooling capacity according to the load
- Adjustable liquid supply temperature with a wide setting range
- SUS304 pipeline with good media compatibility
- Multi functional controller, integrated with temperature, pressure, liquid level and other parameter monitoring
- Power supply and communication interface redundancy
- Supports Modbus RTU communication protocol
Application:
- Heat dissipation of energy storage battery cabinets
- Heat dissipation of energy storage containers
Item | Description | LSJ45 | LSJ4.5 | LSJ8 | LSJ5 | LSJ8 |
Parameters | Customized cooling capacity (kW) | 45 | 4.5 | 8 | 5 | 8 |
Rated heating power (kW) | 8 | 2 | 2.5 | 2.5 | 2.5 | |
Unit type | Vertical | Vertical | Vertical | Horizontal type | Horizontal type | |
Rated flow rate (LPM) | 400 | 30 | 50 | 40 | 50 | |
Refrigeration setting range | 5~25 | |||||
Head (bar) | 28 | 20 | 18 | 15 | 18 | |
Rated power consumption (kW) | 20 | 2.1 | 3.8 | 2.5 | 4.4 | |
Temperature control accuracy (℃) | ±1℃ | |||||
Environmental temperature (℃) | 45 | 35 | 45 | 45 | 45 | |
Supply liquid temperature (℃) | 18 | |||||
Coolant | 50% ethylene glycol aqueous solution | |||||
Refrigerant | R410A | R134A | R134A | R410A | R410A | |
Specification of supply and return liquid interface | 2.5 "Sanitary grade clamp | Aremon NW26 male connector | Aremon NW26 male connector | Aremon NW26 male connector | Aremon NW26 male connector | |
Noise dB(A) | ≤75 | |||||
IP grade | IP54 | |||||
Operating ambient temperature range (℃) | -20~+45℃ | |||||
Electrical parameters | Power spec. | AC380V-3P-50/60Hz | AC220V-1P-50/60Hz | AC220V-1P-50/60Hz | AC220V-1P-50/60Hz | AC220V-1P-50/60Hz |
Control | Chip controller | |||||
MODBUS | RS485,Modbus RTU | |||||
Size W*D*H(mm) | 980×630×2400 | 300×850×1050 | 272×1253×1039 | 830×900×220 | 830×900×310 | |
Weight(kg) | ≤500 | ≤130 | ≤140 | ≤80 | ≤150 |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER