Cold plate thermal performance testing equipment
This product is used for flow resistance and thermal resistance testing of server cold plates. This testing platform integrates modules such as temperature/pressure/flow regulation and monitoring, simulated heat sources, and heat source voltage regulation.
This product is used for flow resistance and thermal resistance testing of server cold plates. This testing platform integrates modules such as temperature/pressure/flow regulation and monitoring, simulated heat sources, and heat source voltage regulation. The maximum heat exchange capacity of the testing platform is 10kW, the flow regulation range is 0.3-15L/min, and the temperature control accuracy is ± 0.5 ℃. This testing platform has two sets of interfaces and can perform thermal or flow resistance tests on two or a single cold plate simultaneously. The testing platform has a simple structure, convenient operation, high integration, high instrument accuracy, and high reliability.
Main Features:
- Can be tested on two or a single cold plate simultaneously
- The temperature control accuracy is within ± 0.5 ℃, and the data reliability is high
- The flow adjustment range is 0.3-15L/min, with a wide adjustment range
- The water pump adopts a one in use and one backup method, with high system reliability
- The liquid supply temperature and flow rate can be flexibly set
- Equipped with an alarm mechanism to assist operation and maintenance personnel in quickly and accurately locating system anomalies
Application:
- Thermal performance testing of liquid cooled plates
Item | Parameters | |
System design parameters | Tested object | Cold plate |
Design pressure level (bar) | 6 | |
Test pressure level (bar) | 8 | |
Flow Condition Range (LPM) | 0.3-15 | |
Flow accuracy (LPM) | ±1 | |
Temperature adjustment range(℃) | 5-65 | |
Precision | ±0.5 | |
Working environment temperature and humidity | 0~50℃/ RH5~85% | |
Storage environment temperature and humidity | -40~65℃/RH5~95% | |
Voltage | 3P AC380V 50Hz | |
Rated power | 4.7kW | |
Communication interfaces and quantity | RS485 | |
MODBUS | Modbus TCP/IP | |
Color | Pantone Cold Grey C11 | |
Interface spec. | Chuck/quick connect | |
Noise | 65dB(A) | |
Weight(kg) | 680 | |
External dimensions (W * D * H) | 1600x1300x2000mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER