IN RACK L2L CDU SERIES
FOR GENERIC SERVERS AND AI SERVERS
NVIDIA H100&B200&GB200 RACKS
BEEHE IN RACK L2L CDU SERIES
FOR GENERIC SERVERS AND AI SERVERS
NVIDIA H100&B200&GB200 RACKS
PRODUCT FEATURES:
- Support ASHRAE W4 warm water cooling, reducing the cold source requirements
- 4RU height, meet EIA and ORV3 racks liquid cooling requirement
- Constant pressure difference, constant flow, constant temperature output control mode
- Small size, strong heat transfer capacity, high heat transfer efficiency
- Adaptive end load changes, automatic adjustment of water and air volume, energy saving and consumption reduction
- Special air-liquid separation design, quickly achieving the first liquid injection and air exhaust of the system, eliminating water pump cavitation
- All SUS304 pipeline, wetted material compatible with PG25/DI water
- Redundant pump, power supply, and controlling sensor, safe and reliable
- The three-level alarm mechanism helps O&M personnel quickly locate system faults
- Under fault switching condition, with slight fluctuations in flow rate, temperature, and pressure difference, smoother temperature control
BEEHE IN RACK L2L CDU TECHNICAL PARAMETERS:
Model |
IR35 |
IR100 |
IR80 |
IR120 |
Cooling object |
Intel/AMD CPU |
H100/B200 |
GB200 NVL36 |
GB200 NVL72 |
Rack type |
EIA |
EIA&ORV3 |
ORV3 |
ORV3 |
Rated cooling capacity |
35kW |
100kW |
80KW |
120kW |
Coolant |
PG25 |
PG25 |
PG25 |
PG25 |
Approach temperature |
10℃ |
5℃ |
5℃ |
4℃ |
Primary side liquid temp.(in/out) |
35℃/46.8℃ |
35℃/49.7℃ |
35℃/47℃ |
36℃/48.8℃ |
Secondary side liquid temp.(out/in) |
45℃/54.6℃ |
40℃/54.2℃ |
40℃/52.3℃ |
40℃/53.2℃ |
Secondary side rated flow rate |
50LPM |
105LPM |
100LPM |
140LPM |
Flow range |
40-100% |
40-100% |
40-100% |
40-100% |
Available Pressure head |
14.5PSI |
18.8PSI |
21.7PSI |
17.4PSI |
Power Supply |
AC90-264V 50/60Hz |
AC90-264V 50/60Hz |
DC48V Busbar |
DC48V Busbar |
Power consumption |
≤0.3kW |
≤1.2kW |
≤1.2kW |
≤1.7kW |
Pump quantity |
1+1 |
1+1 |
1+1 |
1+1 |
Secondary side filter |
100μm |
50μm |
50μm |
50μm |
Communication |
Modbus RTU &TCP/IP |
Modbus RTU &TCP/IP & SNMP & Redfish |
Modbus RTU &TCP/IP & SNMP & Redfish |
Modbus RTU &TCP/IP & SNMP & Redfish |
Weight |
140Ibs |
174Ibs |
176 Ibs |
176Ibs |
Dimensions (W x D x H) |
445x860x177.8mm |
445x860x177.8mm |
536x870x175mm |
536x870x175mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER