IN ROW L2A SIDECAR SERIES
FOR NVIDIA GB200 NVL36/72 RACKS
BEEHE IN ROW L2A SIDECAR SERIES
FOR NVIDIA GB200 NVL36/72 RACKS
PRODUCT FEATURES:
- Special deign for NVIDIA GB200 NVL36/72 racks liquid to air cooling
- Supports ASHRAE A2 air cooling
- Special air-liquid separation design, quickly achieving the first liquid injection and air exhaust of the system, eliminating water pump cavitation
- All SUS304 pipeline, wetted material compatible with PG25/DI water
- Redundant pump, power supply, and controlling sensor, safe and reliable
- Fan N+1 redundancy, online maintenance, large air volume, low noise
- Online maintenance of filters and sensors, friendly operation and maintenance
- Integrated group control function, fault self switching under N+1 configuration, no need for human intervention
- Online monitoring of secondary side liquid quality, automatic alarm for water quality deterioration
- Integrated automatic replenish liquid function, more convenient liquid injection, reducing maintenance frequency
- Under fault switching condition, with slight fluctuations in flow rate, temperature, and pressure difference, smoother
BEEHE SIDECAR PRODUCTS TECHNICAL PARAMETERS:
Model |
IB120 |
IB240 |
Cooling object |
X1 GB200 NVL36 |
X1 GB200 NVL72 |
Rated Cooling capacity |
60kW |
115kW |
Coolant |
PG25 |
PG25 |
Approach temperature |
10℃ |
10℃ |
Primary side liquid temp.(in/out) |
32℃/48.8℃ |
32℃/48.3℃ |
Secondary side liquid temp.(out/in) |
42℃/53.6℃ |
42℃/54.6℃ |
Rated flow rate |
90LPM |
140LPM |
Rated air flow |
7530CFM |
13530CFM |
Flow range |
10-100% |
10-100% |
Available Pressure head |
26PSI |
17.4PSI |
Power Supply |
3P AC177-480V 50/60Hz |
3P AC177-480V 50/60Hz |
Power consumption |
≤3.5kW |
≤6.7kW |
Power quantity |
1+1 |
1+1 |
Pump quantity |
1+1 |
1+1 |
Fan quantity |
N+1 |
N+1 |
Secondary filtration |
25μm |
25μm |
Communication |
Modbus RTU & TCP/IP & SNMP |
Modbus RTU& TCP/IP & SNMP |
Group control |
Optional |
Optional |
Liquid quality monitor |
Yes |
Yes |
Automatic liquid refill |
Yes |
Yes |
Weight |
1058Ibs |
1279Ibs |
Dimensions (W x D x H) |
600 x1200 x2300mm |
800 x1200 x2300mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-