IN ROW L2L CDU SERIES
FOR LIQUID COOLING DATA CENTER
NVIDIA GB200 NVL72 / B200 RACKS
BEEHE IN ROW L2L CDU SERIES
FOR LIQUID COOLING DATA CENTER
NVIDIA GB200 NVL72 / B200 RACKS
PRODUCT FEATURES:
- Special air-liquid separation design, quickly achieving the first liquid injection and air exhaust of the system, eliminating water pump cavitation
- All SUS304 pipeline, wetted material compatible with PG25/DI water
- Redundant pump, power supply, and controlling sensor, safe and reliable
- Online maintenance of filters and sensors, friendly operation and maintenance
- Integrated group control function, fault self switching under N+1 configuration, no need for human intervention
- Online monitoring of secondary side liquid quality, automatic alarm for water quality deterioration
- Integrated automatic replenish liquid function, more convenient liquid injection, reducing maintenance frequency
- Under fault switching condition, with slight fluctuations in flow rate, temperature, and pressure difference, smoother temperature control
BEEHE IN ROW CDU PRODUCTS TECHNICAL PARAMETERS:
Model |
IB300 |
IB600 |
IB1200 |
IB1800 |
Cooling object |
X4 GB200 NVL36 |
X4 GB200 NVL72 |
X8 GB200 NVL72 |
X16 GB200 NVL72 |
Rated Cooling capacity |
300kW |
600kW |
1200kW |
1800kW |
Coolant |
PG25 |
PG25 |
PG25 |
PG25 |
Approach temperature |
5℃ |
5℃ |
4℃ |
4℃ |
Primary side liquid temp.(in/out) |
35℃/46℃ |
35℃/43.2℃ |
35℃/45.2℃ |
35℃/45.2℃ |
Secondary side liquid temp.(out/in) |
40℃/51℃ |
40℃/50.3℃ |
39℃/49.3℃ |
39℃/50.3℃ |
Secondary side rated flow rate |
445LPM |
900LPM |
1800LPM |
2400LPM |
Flow range |
10-100% |
10-100% |
10-100% |
10-100% |
Available Pressure head |
21.7PSI |
36.2PSI |
36.2PSI |
36.2PSI |
Power Supply option 1 |
3P AC380V 50/60Hz |
3P AC380V 50/60Hz |
3P AC380V 50/60Hz |
3P AC380V 50/60Hz |
Power Supply option 1 |
3P AC480V 60Hz |
3P AC480V 60Hz |
3P AC480V 60Hz |
3P AC480V 60Hz |
Power consumption |
≤5.5kW |
≤12.8kW |
≤20kW |
≤32.5kW |
Dual power ATS |
Yes |
Yes |
Yes |
Yes |
Frequency converter quantity |
1+1 |
1+1 |
1+1 |
1+1 |
Pump quantity |
1+1 |
1+1 |
1+1 |
1+1 |
Secondary side filter |
100μm |
50μm |
50μm |
50μm |
Primary side filter |
500μm |
500μm |
200μm |
200μm |
Communication |
Modbus RTU&TCP/IP |
Modbus RTU&TCP/IP |
Modbus RTU&TCP/IP |
Modbus RTU&TCP/IP |
Group control |
Yes |
Yes |
Yes |
Yes |
Liquid quality monitor |
Yes |
Yes |
Yes |
Yes |
Automatic liquid refill |
Yes |
Yes |
Yes |
Yes |
Weight |
1297Ibs |
3528Ibs |
4565Ibs |
4708Ibs |
Dimensions (W x D x H) |
600 x1200 x2300mm |
800 x2000 x2000mm |
1000 x2000 x2000mm |
1200 x2000 x2000mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER