Before conducting water supply management and overall testing on server cabinets, drain, dry, and inject nitrogen into the liquid cooling channels inside the cabinets. Can be used to drain, dry, and inject nitrogen into two cabinets and two nodes. The equipment integrates temperature, humidity, and pressure instruments for monitoring; Using a proportional control valve for pressure regulation to ensure stable gas supply; Equipped with a heater, it can regulate the gas temperature and achieve good drying efficiency; Internally integrated oil-free vacuum pump, with reliable performance and long service life.
Features:
- Conduct testing on 2 cabinets or 2 nodes
- Using electrical proportional valves for gas source control to ensure stable input nitrogen/air pressure
- Adopting a heater for stepless speed regulation and high drying efficiency
- SUS304 stainless steel pipeline has high pressure bearing capacity and high reliability
- 21 inch display screen for easy data reading
- Equipped with an alarm mechanism to assist operation and maintenance personnel in quickly and accurately locating system anomalies
Application:
- Liquid cooling server node drainage, drying, and nitrogen injection
- Drain, dry and inject nitrogen into the liquid cooling cabinet
Item |
Parameters |
|
System design parameters |
Purging medium type |
Compressed air |
Drainage and intake pressure |
≤0.7(Mpa) |
|
Draining time |
cabinet≤5min/cabinet 1min/node |
|
Drying medium |
Compressed hot air |
|
Media filtration accuracy |
<0.01μm |
|
Drying inlet temperature range |
40-80℃ |
|
Heater power |
≤4.5kW |
|
Temperature regulation accuracy |
+/-5℃ |
|
Drying time |
≤30min/cabinet ≤10min/node |
|
Drying qualified humidity determination |
<28% RH(@40℃ relative humidity) |
|
Drying pipeline interface form |
Matching with cabinet interface |
|
Nitrogen injection medium |
Industrial pure nitrogen |
|
Nitrogen injection pressure |
30~60kPa |
|
Nitrogen injection process time |
≤10min/cabinet |
|
Time for vacuum |
Cabinet≤30min/cabinet Node≤25min/node |
|
System vacuum requirements |
≤5pa |
|
Vacuum gauge accuracy |
1*10-1pa*10+4pa±20% |
|
Independently control the number of channels |
2 channels (2 cabinets or 2 nodes) |
|
Design pressure (PSI/bar)*2 |
102/8 |
|
Test pressure (PSI/bar) |
102/10 |
|
Weight (kg/lbs) |
600/1323 |
|
Working environment temperature and humidity |
-20~45℃/ RH5~85% |
|
Storage environment temperature and humidity |
-40~65℃/RH5~95% |
|
Power interface |
Aviation connector |
|
Max. power consumption |
≤5.5kW |
|
Communication interfaces and quantity |
RJ45/6 |
|
Modbus |
Modbus TCP/IP |
|
Interface specifications |
Chuck/quick connect |
|
Color |
Pantone Cold Grey C11 |
|
External dimensions (height * width * depth) |
1490x800x1400mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER