Rear door liquid cooling
The liquid cooled backplate door integrates the heat exchange system into the back door of the server cabinet, using an efficient copper tube aluminum fin heat exchanger. The reasonable fin spacing design, special thickened copper tubes, and scientific pipeline process design make the entire heat exchange system have extremely low resistance, bringing efficient heat exchange performance. When the internal server of the cabinet is working, the heat generated by electronic components is discharged to the surface of the liquid cooled back door radiator fins through a fan. The heat is absorbed by the low-temperature cooling water inside the heat exchanger pipeline and carried out of the data center. The absorbed high-temperature cooling water is cooled by an external cooling water tower and then returned to the interior of the liquid cooled back door to start the next cycle.
Features:
- Rated cooling capacity 10-60kW
- Active/passive optional
- Adopting special thickened copper pipes, with strong corrosion resistance, high pressure bearing capacity, and high reliability
- Supply and return liquid chuck type connection, easy to install and maintain
- The bottom comes with casters, making it easy to open and close doors
- Adopting a special hinge design, it fully meets the load-bearing requirements of the liquid cooled back door
Application:
- Server cooling
- Switch heat dissipation
Item |
Description |
Parameters |
Parameters |
System design parameters |
Type |
Active |
Passive |
Cooling capacity |
59kW |
14kW |
|
Adapt to server cabinets |
42U |
42U |
|
Compatible with cooling media |
Pure water/PG25 |
Pure water/PG25 |
|
Power |
90-264VAC 50/60Hz |
/ |
|
Max. power consumption |
1.3kW |
/ |
|
Inlet air temperature/humidity |
45℃/RH20% |
45℃/RH20% |
|
Air intake volume |
8100m³/h |
4056m³/h |
|
Rated inlet temperature |
14℃ |
32℃ |
|
Rated liquid inlet flow rate |
100L/min |
90L/min |
|
Import and export specifications |
1''chuck |
1'' chuck |
|
Interface location |
Bottom |
Bottom |
|
Weight |
<100kg |
<90kg |
|
External dimensions (width * depth * height) |
597x225x2060mm |
597x225x2060mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER