IN RACK L2L CDU SERIES
FOR GENERIC SERVERS AND AI SERVERS
NVIDIA GB200 & GB300 & VR RUBIN RACKS
BEEHE IN RACK L2L CDU SERIES
FOR GENERIC SERVERS AND AI SERVERS
NVIDIA GB200 & GB300 & VR RUBIN RACKS
PRODUCT FEATURES:
- Support ASHRAE W4 warm water cooling, reducing the cold source requirements
- 4RU height, meet EIA and ORV3 racks liquid cooling requirement
- Constant pressure difference, constant flow, constant temperature output control mode
- Small size, strong heat transfer capacity, high heat transfer efficiency
- Adaptive end load changes, automatic adjustment of water and air volume, energy saving and consumption reduction
- Special air-liquid separation design, quickly achieving the first liquid injection and air exhaust of the system, eliminating water pump cavitation
- All SUS304 pipeline, wetted material compatible with PG25/DI water
- Redundant pump, power supply, and controlling sensor, safe and reliable
- The three-level alarm mechanism helps O&M personnel quickly locate system faults
- Under fault switching condition, with slight fluctuations in flow rate, temperature, and pressure difference, smoother temperature control
BEEHE IN RACK L2L CDU TECHNICAL PARAMETERS:
|
Model |
IR35 |
IR100 |
IR100P |
IR120 |
IR200 |
IR300 |
|
Cooling object |
CPU Server |
B200/B300 |
GB200/GB300 |
GB300 |
Vera Rubin |
Vera Rubin |
|
Rack type |
EIA |
EIA |
ORV3 |
ORV3 |
EIA&ORV3 |
EIA&ORV3 |
|
Rated cooling capacity |
35kW |
100kW |
130kW |
120kW |
200KW |
300KW |
|
Coolant |
PG25 |
PG25 |
PG25 |
PG25 |
PG25 |
PG25 |
|
Approach temperature |
5℃ |
5℃ |
5℃ |
4℃ |
5℃ |
4℃ |
|
Primary side air temp.(in/out) |
35℃/45.8℃ |
35℃/45.7℃ |
35℃/45.7℃ |
36℃/48.8℃ |
35℃/50℃ |
36℃/48.9℃ |
|
Secondary side liquid temp.(out/in) |
45℃/50.8℃ |
40℃/55.7℃ |
40℃/55.7℃ |
40℃/52.8℃ |
40℃/55℃ |
40℃/55℃ |
|
Secondary side rated flow rate |
50LPM |
105LPM |
130LPM |
140LPM |
200LPM |
300LPM |
|
Flow range |
40-100% |
40-100% |
40-100% |
40-100% |
40-100% |
40-100% |
|
Available Pressure head |
17.4PSI |
26.1PSI |
26.1PSI |
17.4PSI |
21.7PSI |
23.3PSI |
|
Power Supply |
AC220V 50/60Hz |
AC2200V 50/60Hz |
DC48V Busbar |
DC48V Busbar |
AC220V 50/60Hz |
AC220V 50/60Hz |
|
Power consumption |
≤0.5kW |
≤1.3Kw |
≤1.5kW |
≤1.7kW |
≤2.7KW |
≤3.2KW |
|
Pump quantity |
1+1 |
1+1 |
1+1 |
1+1 |
1+1 |
1+1 |
|
Secondary side filter |
100μm |
50μm |
50μm |
50μm |
25μm |
25μm |
|
Communication |
Modbus RTU &TCP/IP |
Modbus RTU &TCP/IP & SNMP |
Modbus RTU &TCP/IP & SNMP |
Modbus RTU &TCP/IP & SNMP |
Modbus RTU &TCP/IP & SNMP & Redfish |
Modbus RTU &TCP/IP & SNMP& Redfish |
|
Weight |
94.6Ibs |
174Ibs |
176Ibs |
191.8Ibs |
180Ibs |
220.5lbs |
|
Dimensions (W x D x H) |
445x860x177.8 mm |
445x850x192 mm |
445x850x192 mm |
536x870x175 mm |
445x850x192 mm |
445x850x266.7 mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
RDHX
-
Manifold
-
Liquid cooling pipeline
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER