IN ROW L2L CDU SERIES
FOR LIQUID COOLING DATA CENTER
NVIDIA GB200 / GB300 / VERA RUBIN RACKS
BEEHE IN ROW L2L CDU SERIES
FOR LIQUID COOLING DATA CENTER
NVIDIA GB200 / GB300 / VERA RUBIN RACKS
PRODUCT FEATURES:
- Special air-liquid separation design, quickly achieving the first liquid injection and air exhaust of the system, eliminating water pump cavitation
- All SUS304 pipeline, wetted material compatible with PG25/DI water
- Redundant pump, power supply, and controlling sensor, safe and reliable
- Online maintenance of filters and sensors, friendly operation and maintenance
- Integrated group control function, fault self switching under N+1 configuration, no need for human intervention
- Online monitoring of secondary side liquid quality, automatic alarm for water quality deterioration
- Integrated automatic replenish liquid function, more convenient liquid injection, reducing maintenance frequency
- Under fault switching condition, with slight fluctuations in flow rate, temperature, and pressure difference, smoother temperature control
BEEHE IN ROW L2L CDU PRODUCTS TECHNICAL PARAMETERS:
|
Model |
IB300 |
IB600 |
IB1350/IB1350P |
IB1800 |
IP5000 |
IP10000 |
|
Cooling object |
B200&B300 |
GB200 |
GB200 / GB300 |
GB300 /VR RUBIN |
VR RUBIN |
VR RUBIN |
|
Rated Cooling capacity |
300kW |
600kW |
1350kW |
1800kW |
4.6MW |
9.6MW |
|
Coolant |
PG25 |
PG25 |
PG25 |
PG25 |
PG25 |
PG25 |
|
Approach temperature |
5℃ |
5℃ |
4℃ |
4℃ |
2℃ |
2℃ |
|
Primary side liquid temp.(in/out) |
35℃/46℃ |
35℃/43.2℃ |
35℃/47.5℃ |
35℃/45.2℃ |
43℃/53℃ |
43℃/53℃ |
|
Secondary side liquid temp.(out/in) |
40℃/51℃ |
40℃/50.1℃ |
39℃/53℃ |
39℃/50.3℃ |
45℃/55.5℃ |
45℃/55.5℃ |
|
Secondary side rated flow rate |
445LPM |
900LPM |
1440LPM/1800LPM |
2400LPM |
6625LPM |
13250LPM |
|
Flow range |
10-100% |
10-100% |
10-100% |
10-100% |
10-100% |
10-100% |
|
Available Pressure head |
21.7PSI |
36PSI |
36PSI |
42PSI |
36PSI |
36PSI |
|
Power Supply |
3P AC380V 50/60Hz 3P AC480V 60Hz |
3P AC380V 50/60Hz 3P AC480V 60Hz |
3P AC380V 50/60Hz 3P AC480V 60Hz |
3P AC380V50/60Hz 3P AC480V 60Hz |
3P AC380V50/60Hz 3P AC480V 60Hz |
3P AC380V50/60Hz 3P AC480V 60Hz |
|
Power consumption |
≤5.5kW |
≤12.2kW |
≤19kW / ≤25kW |
≤32.8kW |
≤170kW |
≤260kW |
|
Dual power ATS |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Pump quantity |
1+1 |
1+1 |
1+1 |
1+1 |
1+1 |
1+1 |
|
Secondary side filter |
100μm |
50μm |
50μm |
50μm |
25μm |
25μm |
|
Bypass filter |
/ |
/ |
Optional |
Optional |
1μm |
1μm |
|
Primary side filter |
500μm |
500μm |
500μm |
500μm |
500μm |
500μm |
|
Communication |
Modbus RTU&TCP /IP&SNMP |
Modbus RTU&TCP /IP&SNMP |
Modbus RTU&TCP /IP&SNMP |
Modbus RTU&TCP /IP&SNMP |
Modbus RTU&TCP /IP&SNMP |
Modbus RTU&TCP /IP&SNMP |
|
Group control |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Liquid quality monitor |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Automatic liquid refill |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Weight |
1297Ibs |
1763.7Ibs |
3351.1Ibs / 4708Ibs |
5070.6Ibs |
23100Ibs |
34650Ibs |
|
Dimensions (W x D x H) |
600 x1200 x2300mm |
800 x2000x2000mm |
900 x1450 x2100mm /1200*1800*2100mm |
1200 x2000 x2000mm |
2300 x6000 x2400mm |
2300 x12000 x2400mm |




-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
RDHX
-
Manifold
-
Liquid cooling pipeline
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER