REAR DOOR HEAT EXCHANGER
BEEHE REAR DOOR HEAT EXCHANGER PRODUCTS FOR LIQUID COOLING DATA CENTER
PRODUCTS FEATURES:
- Enhanced pure copper heat exchange coil: high pressure resistance and reliability.
- Special flow channel and heat exchange fin design: Lower flow resistance and higher heat exchange efficiency.
- Integrated control system: Monitors temperature, humidity, pressure, and liquid leakage. Automatically adjusts fan speed and liquid intake flow.
- Multi-axial flow fan design: N+1 safety redundancy configuration, allows for online maintenance, low noise, and high air volume.
- Modular design: Adapter compatible with various types of racks.
- Compatible with top and bottom water inlet/outlet pipes: Suitable for different application scenarios.
- Optional dual power supply redundancy.
RDHX PRODUCTS TECHNICAL SPECIFICATION:
|
Model |
RDHX30-A2D-LT1C |
RDHX50-A2D-LT1C |
RDHX55-A2D-LT1C |
RDHX75-A2D-LT1C |
||||
|
Compatible Rack Widths |
600mm |
800mm |
||||||
|
Compatible Rack Heights |
2000mm (fits 42U) |
2200mm (fits 47U) |
2324mm (fits 48U) |
2481mm (fits 52U) |
||||
|
Depth |
210mm |
230mm |
||||||
|
Rated Cooling capacity |
30kW |
50kW |
55kW |
75kW |
||||
|
Coolant |
DB air |
PG25 |
DB air |
PG25 |
DB air |
PG25 |
DB air |
PG25 |
|
Flow rate (Air: m³/h/cfm) & (Liquid: lpm/usgpm) |
5000/2941 |
55/14.5 |
7800/4588 |
78.3/20.7 |
8500/5000 |
82.2/21.7 |
12100/7122 |
143/37.8 |
|
Rated inlet temperature (℃/℉) |
45/113 |
14/57.2 |
45/113 |
14/57.2 |
45/113 |
14/57.2 |
45/113 |
14/57.2 |
|
Rated outlet temperature (℃/℉) |
25/95 |
23/73.7 |
25/95 |
24/75 |
25/95 |
24.5/76 |
25/95 |
22/71.6 |
|
Pressure drops |
76 |
53 |
115 |
61 |
73 |
52 |
96 |
78 |
|
Power specifications |
90~290V AC 50/60HZ |
|||||||
|
Power consumption |
≤1.4kW |
≤1.6kW |
≤3.4kW |
≤5kW |
||||
|
Power interface |
C20 |
C20 |
C20 |
C20 |
||||
|
Fan diameter |
120mm |
200mm |
||||||
|
Number of fans |
16 |
18 |
10 |
10 |
||||
|
Fan quantity |
N+1 |
|||||||
|
Working environment T&H |
0~55℃/ RH5~90% |
|||||||
|
Storage environment T&H |
-45~70℃/RH5~93% |
|||||||
|
Communication |
RS485 /RJ45/ Modbus RTU |
RS485 /RJ45/ Modbus RTU |
RS485 /RJ45/ Modbus RTU |
RS485 /RJ45/ Modbus RTU |
||||
|
Design pressure(bar/psi) |
10/145 |
10/145 |
10/145 |
10/145 |
||||
|
Weight(Kg/Ibs) |
102/224.87 |
119/262.4 |
142/313 |
160/352.7 |
||||
|
Connection type |
1 " clamp |
1 " clamp |
1 " clamp |
1 " clamp |
||||
|
Monitoring parameter |
Temperature, pressure, condensation, |
|||||||


-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
RDHX
-
Manifold
-
Liquid cooling pipeline
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER