Liquid cooling EDU
The liquid cooled EDU integrates control, power, buffering, and heat exchange systems. It continuously pumps a constant pressure and flow of cooling medium into the supply side pipeline through a circulating pump. The cooling medium is evenly distributed to each rack through the machine room level manifold. The cooling medium flows through the server node to export heat and then converges to the return side pipeline. The heat is exchanged with the cold air in the primary side machine room through the primary side CDU, and then exported to the machine room environment. Finally, the heat is exported to the external environment through the air conditioning in the data center machine room. The cooled cooling medium flows back to the circulation pump, is pressurized by the circulation pump, and then re-enters the supply side ring network pipeline, forming a closed circulating cooling circuit.
Features:
- Platform based design, high integration, easy deployment and maintenance
- Integrated pump drive function, providing primary circulation power
- Integrated impurity filtration function to ensure system cleanliness
- Integrated water quality management function, effectively ensuring the primary side water quality
- Integrate voltage stabilization and constant pressure replenishment functions to reduce system operation and maintenance
- Integrate group control functions and coordinate with the data center group control
Application:
- Liquid cooled data center primary side
Item | Parameters | |
System design parameters | Rated cooling capacity | 242kW |
Rated operating point | 28.8m3/h | |
Design pressure | 1.0MPa | |
Rated pressure | 3P 380V 50/60Hz | |
System rated pressure | 6.5kW | |
Internal circulation process design parameters | Cooling medium | PG-25 |
Rated liquid supply flow rate of the pump | 28.8m3/h | |
Temperature difference between supply and return liquid | 10℃ | |
Design of liquid supply pump | Single pump design, system level redundancy design | |
Secondary side pipeline | Ring network design | |
Filtration | ≤50μm | |
Static pressure of buffer tank | ≤1.5 bar | |
External dimensions of CDU (width x depth x height) | 800×1200×2100mm |
-
ꄶ LIQUID COOLING
-
In Rack L2A CDU
-
In Row L2A Sidecar
-
In Rack L2L CDU
-
In Row L2L CDU
-
Rear door liquid cooling
-
Manifold
-
Liquid cooling loop
-
Immersion liquid cooling CDU&Tank
-
Liquid cooling cabinet
-
Liquid cooling EDU
-
Closed cooling tower
-
Mobile refill cart
-
Liquid cooling server pressure maintain
-
Server cleaning and injection equipment
-
Server drain-dry-nitrogen injection
-
Server test equipment transfer box
-
Cold plate thermal performance testing
-
Water purifier
-
-
ꄶ HEAT EXTRACTION
-
ꄶ FLUID CONTROL COMPONENT
-
ꄶ AIR COOLING
-
ꄶ HEATER